3eme Avis de clarifications pour la consultation PP24-036
MINISTERE DE L’INDUSTRIE, DE L’ENERGIE ET DES MINES
COMPAGNIE TUNISIENNE DE FORAGE CTF
CLARIFICATIONS related TO inquiry N° PP 2024/036
INVITATION TO BID N° PP 2024/036
SUPPLY OF 01 HIGH PRESSURE BOP CONTROL UNIT
New information from our technical team:
– the Rate Work Pressure of the accumulator unit is 3000 PSI as a minimum required
-Correct closing unit pressure ratio of the BOP 7.11
-Shear pressure: between 1500 to 3000 PSI depending of maximum anticipated surface pressure and the mud density
– The maximum diameter of Piston area is 14 inch
-The maximum diameter of DP is 5″ grad S135 W= 19.5 lbs/ft